Basic features |
| Technical features |
Description |
References |
| Standard Dongle(Editing+Rhythm analysis + ST analysis |
Signal analysis,rhythm analysis,ST segment analysis,editing and corrections of QRS templates,events,ECG display,histogram,pre_written conclusion,report editing |
KLQ-07-A |
| Standard dongle + pacemaker |
As above + a program that detects spikes on the ECG with an automatic classification of paced QRS. Screen analysis of specific modes and spikes/spikes timing (spontaneous rhythm,single or dual chamber pacemaker. |
KLQ-15-A |
| Dongle with tokens |
Alternative to permanent license with the same features for analysis. For each patient analysed,the counter of tokens is decreased. |
KLQ-XX-J |
| Quick Reader license |
The same as standard dongle but with a asoft key instead of the dongle.Same option as for dongle |
KLQ-0700KLQ-1500 |
Complementary options |
| Technical features |
Description |
References |
| Heart rate variability option(HRV) |
Calculate the power contained in frequency bans from 0.00 to 0.5Hz of the heart rate curve with VLF,LF and HF cumulated values. The analysis period may be selected from a minimum of 15 seconds to the entire recording. printing results on demand. |
KLQ-10-A |
| P and T wave analysis |
Provides the f(t) trends of the PR and QT intervals(if the wave amplitude is sufficient),the amplitude of the P and T waves,and graphic PR/RR and QT/RR + regression line. The analysis period may be selected from 15' to the length of the recording. Printing results on demand. |
KLQ-20-A |
| Export data |
Export the results of the analysis to database |
KLQ-40-A |
| Sleep apnoea analysis |
Analyse the respiratory,respiratory frequency,the level of snoring and apnoea. Print a report giving the apnoea index and hourly average,with the average and maximum apnoea duration. The record must be done with a RXT00-2L3-250 cable. |
KLQ-80-A |
| Security option with administrator |
Password protected access. |
KLQ-100-A |
Network use |
| Technical features |
Description |
References |
| Master dongle |
Devoted to the main PC,generally the one used to download files. |
KLQ-015-E |
| Slave dongle |
Possibility to find patient files through the network. if the initial analysis is done on the master station,nothing changes. But if the initial analysis is done on the slave station, a token is removed for each analysis.As a dongle contains 10 tokens, it will gradually deplete it's stock. The suer has to reload in on the main station |
KLQ-015-M |